Maritime

PROJECT CASE STUDY

Intermodal Terminal of Trieste (TRS)

ABOUT TRS:

As with most intermodal terminals, TRS operates 24/7. So, lighting is critical. Traditional High Pressure Sodium lighting systems are costly to maintain and offer poor colour rendering for CCTV systems. Another reason for switching to LED lighting is to reduce neighbourhood light pollution. TRS asked us to upgrade their lighting to make sure it was delivering exactly what was needed for an intermodal terminal.

OUR SOLUTION

We replaced 1,000W sodium projectors with 455W LED technology. And the number of units was cut from 60 to 47 too. The result? High uniform light levels across the whole yard – without any light pollution for the neighbours.

PROJECT OVERVIEW

Sector:

Maritime

Customer:

TRS Intermodal Terminal

Location:

Italy

Working area:

130,000m2

Hours of Operation:

24/7

Project date:

2016

LED floodlights installed:

47

Type:

Titan Series

Mast Height:

37.5m

Energy savings:

73%

47

LED floodlights installed

24/7

Hours of Operation

73%

Energy savings

130,000m2

Working Area

BEFORE & AFTER TECHNICAL COMPARISON

SODIUMLED
Number of Projectors6047
Nominal Power for single appliance1,000W455W
Absorbed Power(measured data)1,315W455W
Total Power Absorbed81.5 kW21.3 kW
Energy Consumption per year357,100 kWh93,600 kWh
Colour temperature2,300K5,700K
Colour rendering index3070
Average light level10 Lux20 Lux
Uniformity0.190.28
Energy savings73%

Download Case Study